DC-Link Capacitor Precharge Time Calculator method
Compare 3τ and 5τ for a 650 V drive DC link and find how the higher voltage target narrows the resistor range.
The model assumes a stiff DC source, an initially discharged DC link, negligible series resistance besides the precharge resistor and no downstream load during precharge. The lower nominal resistance bound respects initial current at the low tolerance limit. The upper bound respects the timeout at the high tolerance limit.
The largest E24 value in range minimizes peak current among those preferred values. E12 and E24 indicate nominal values. Use the actual part tolerance, working voltage, transient pulse curve, enclosure temperature and repetition allowance. The rated demand divides by the available rating fraction at the chosen ambient temperature.
The window starts when the high-tolerance resistor reaches the chosen voltage threshold. Confirm the bus-to-pack difference independently before main-contactor closure. The acceptable voltage difference depends on the contactor making rating, bus capacitance and commutation path.
Formulas
τ = R × C; Vbus(t) = Vpack × (1 − exp(−t/τ)); I(t) = (Vpack/R) × exp(−t/τ)N = −ln(1 − target fraction); Rmin = Vpack / (Ilimit × (1 − tolerance)); Rmax = timeout / (N × C × (1 + tolerance))Efull = ½ × C × Vpack²; Ethreshold = Efull × (1 − exp(−2N)); Ppeak = Vpack² / RlowAverage over a charge pulse = Ethreshold / tclose; cycle average = Efull / repeat interval; required rating = worst demand × safety factor / ambient rating fraction
Worked example
The starting scenario gives a nominal range of 68.42–144.3 Ω, a 130 Ω E24 match and a full-charge resistor pulse of 464.75 J.