ESS Precharge Resistor Pulse Energy Calculator

Estimate pulse and cycle-average power for a warm storage enclosure that repeatedly energizes a 720 V DC bus.

Jump to results

Inputs

DC-link and timing
Use the worst-case total downstream capacitance.
Example targets are 90% and 95%.
Use the lowest applicable limit of the precharge path.
Resistor selection and cooling
Include temperature drift in the worst-case tolerance.
Illustrative multiplier for all rating estimates.
Enter the applicable datasheet percentage at this temperature. The calculator uses this factor for every rating as a screening assumption.

Results

Estimates
Nominal resistor range63.16–264.93 Ω
Inrush lower bound
63.16 Ω
Timeout upper bound
264.93 Ω
Largest E12 match
220 Ω
Largest E24 match
240 Ω
Target bus voltage / remaining ΔV
684 V (95%) / 36 V
Full / threshold pulse energy
777.6 J / 775.66 J
Required full-pulse energy rating
1,555.2 J
Cycle average / required rating
77.76 W / 155.52 W
Modeled resistance
240 Ω
Nominal / highest initial current
3 A / 3.16 A
Worst peak / required rating
2,273.68 W / 4,547.37 W
Nominal pulse average / required rating
359.61 W / 757.08 W
High-tolerance threshold to timeout
2.2648–2.5 s
Available closing time
0.2352 s
Nominal DC-link voltage and precharge current
0 0 360 1.5 720 3V A 0 Time (s) 2.5
  • DC-link voltage
  • Resistor current

0 s · DC-link voltage 0 V · Resistor current 3 A

Rating demands include the entered safety and ambient factors at 55 °C. Confirm the actual voltage difference before closing.

ESS Precharge Resistor Pulse Energy Calculator method

Estimate pulse and cycle-average power for a warm storage enclosure that repeatedly energizes a 720 V DC bus.

The model assumes a stiff DC source, an initially discharged DC link, negligible series resistance besides the precharge resistor and no downstream load during precharge. The lower nominal resistance bound respects initial current at the low tolerance limit. The upper bound respects the timeout at the high tolerance limit.

The largest E24 value in range minimizes peak current among those preferred values. E12 and E24 indicate nominal values. Use the actual part tolerance, working voltage, transient pulse curve, enclosure temperature and repetition allowance. The rated demand divides by the available rating fraction at the chosen ambient temperature.

The window starts when the high-tolerance resistor reaches the chosen voltage threshold. Confirm the bus-to-pack difference independently before main-contactor closure. The acceptable voltage difference depends on the contactor making rating, bus capacitance and commutation path.

Formulas

  • τ = R × C; Vbus(t) = Vpack × (1 − exp(−t/τ)); I(t) = (Vpack/R) × exp(−t/τ)
  • N = −ln(1 − target fraction); Rmin = Vpack / (Ilimit × (1 − tolerance)); Rmax = timeout / (N × C × (1 + tolerance))
  • Efull = ½ × C × Vpack²; Ethreshold = Efull × (1 − exp(−2N)); Ppeak = Vpack² / Rlow
  • Average over a charge pulse = Ethreshold / tclose; cycle average = Efull / repeat interval; required rating = worst demand × safety factor / ambient rating fraction

Worked example

The starting scenario gives a nominal range of 63.16–264.93 Ω, a 240 Ω E24 match and a full-charge resistor pulse of 777.6 J.

Engineering references

Frequently asked questions

What happens to cycle-average watts when the restart interval halves?

With the same full-charge energy per start, cycle-average power doubles. Check the part’s repetitive-pulse limits for the actual duty.

In the ESS Precharge Resistor Pulse Energy Calculator example, what does 3τ or 5τ mean in DC-link precharge?

Three time constants reach about 95.02% of pack voltage. Five reach about 99.33%.

In the ESS Precharge Resistor Pulse Energy Calculator example, why are pulse watts and continuous watts different?

The resistor sees its highest power at switch-on. The repeated-cycle average depends on the energy dissipated and the interval between starts. Check both against the relevant part curves.