Precharge Contactor Closing Voltage Window

See how a 98% voltage threshold and ±10% resistance tolerance affect an EV contactor closing window.

Jump to results

Inputs

DC-link and timing
Use the worst-case total downstream capacitance.
Example targets are 90% and 95%.
Use the lowest applicable limit of the precharge path.
Resistor selection and cooling
Include temperature drift in the worst-case tolerance.
Illustrative multiplier for all rating estimates.
Enter the applicable datasheet percentage at this temperature. The calculator uses this factor for every rating as a screening assumption.

Results

Estimates
Nominal resistor range92.59–174.29 Ω
Inrush lower bound
92.59 Ω
Timeout upper bound
174.29 Ω
Largest E12 match
150 Ω
Largest E24 match
160 Ω
Target bus voltage / remaining ΔV
490 V (98%) / 10 V
Full / threshold pulse energy
150 J / 149.94 J
Required full-pulse energy rating
225 J
Cycle average / required rating
5 W / 7.5 W
Modeled resistance
160 Ω
Nominal / highest initial current
3.13 A / 3.47 A
Worst peak / required rating
1,736.11 W / 2,604.17 W
Nominal pulse average / required rating
199.62 W / 332.71 W
High-tolerance threshold to timeout
0.8262–0.9 s
Available closing time
0.0738 s
Nominal DC-link voltage and precharge current
0 0 250 1.563 500 3.125V A 0 Time (s) 0.9
  • DC-link voltage
  • Resistor current

0 s · DC-link voltage 0 V · Resistor current 3.125 A

Rating demands include the entered safety and ambient factors at 25 °C. Confirm the actual voltage difference before closing.

Precharge Contactor Closing Voltage Window method

See how a 98% voltage threshold and ±10% resistance tolerance affect an EV contactor closing window.

The model assumes a stiff DC source, an initially discharged DC link, negligible series resistance besides the precharge resistor and no downstream load during precharge. The lower nominal resistance bound respects initial current at the low tolerance limit. The upper bound respects the timeout at the high tolerance limit.

The largest E24 value in range minimizes peak current among those preferred values. E12 and E24 indicate nominal values. Use the actual part tolerance, working voltage, transient pulse curve, enclosure temperature and repetition allowance. The rated demand divides by the available rating fraction at the chosen ambient temperature.

The window starts when the high-tolerance resistor reaches the chosen voltage threshold. Confirm the bus-to-pack difference independently before main-contactor closure. The acceptable voltage difference depends on the contactor making rating, bus capacitance and commutation path.

Formulas

  • τ = R × C; Vbus(t) = Vpack × (1 − exp(−t/τ)); I(t) = (Vpack/R) × exp(−t/τ)
  • N = −ln(1 − target fraction); Rmin = Vpack / (Ilimit × (1 − tolerance)); Rmax = timeout / (N × C × (1 + tolerance))
  • Efull = ½ × C × Vpack²; Ethreshold = Efull × (1 − exp(−2N)); Ppeak = Vpack² / Rlow
  • Average over a charge pulse = Ethreshold / tclose; cycle average = Efull / repeat interval; required rating = worst demand × safety factor / ambient rating fraction

Worked example

The starting scenario gives a nominal range of 92.59–174.29 Ω, a 160 Ω E24 match and a full-charge resistor pulse of 150 J.

Engineering references

Frequently asked questions

What if the high-tolerance crossing occurs at the timeout?

The available closing window is zero in the ideal model. Account for measurement filtering, contactor response and controller timing jitter.

In the Precharge Contactor Closing Voltage Window example, what does 3τ or 5τ mean in DC-link precharge?

Three time constants reach about 95.02% of pack voltage. Five reach about 99.33%.

In the Precharge Contactor Closing Voltage Window example, why are pulse watts and continuous watts different?

The resistor sees its highest power at switch-on. The repeated-cycle average depends on the energy dissipated and the interval between starts. Check both against the relevant part curves.