12V DC Rooftop RV Air Conditioner Runtime on 200Ah LiFePO4 Calculator

Check how many hours a variable-speed 12 V DC van air conditioner runs at 650 W Eco vs. 950 W Max cooling on a 200 Ah (or 400 Ah) 12.8 V LFP bank.

Jump to results

Inputs

Instant energy converter
Appliance runtime simulator

Results

Estimates
Estimated appliance runtime3:21 h:mm
Usable battery energy
2,176 Wh
Battery-side draw
650 W
Converted energy
2.56 kWh
Converted watt-hours
2,560 Wh
Converted amp-hours
200 Ah
Conversion voltage
12.8 V
Nameplate and usable battery energy
Nameplate energy 2,560 Wh Usable energy 2,176 Wh

With zero battery-side draw, there is no load-limited runtime. Include inverter standby and use measured duty-cycle power for variable loads.

See realistically why off-grid van air conditioning demands 400+ Ah or 24 V/48 V banks

Inverter-driven 12 V DC rooftop van ACs eliminate AC inverter losses, yet cooling a sun-baked vehicle still requires 450–700 W steady on Eco mode and 850–1,100 W at max midday heat.

At 650 W continuous on a 12.8 V 200 Ah LiFePO4 pack (2,176 Wh usable @ 85% DoD), runtime is 3.35 hours (2.29 h at 950 W max)—extending to 6.70 hours overnight once doubled to 400 Ah.

Formulas

  • Usable energy = 200 Ah × 12.8 V × 85% DoD = 2,176 Wh
  • 650 W Eco DC runtime = 3.35 hours (2.29 h @ 950 W Max)
  • 400 Ah bank (4,352 Wh usable) @ 650 W = 6.70 hours

Worked example

A 200 Ah 12.8 V bank (2,176 Wh usable) runs a 650 W 12 V Eco AC for 3.35 hours or 2.29 hours at 950 W; stepping up to 400 Ah doubles Eco runtime to 6.70 hours.

Frequently asked questions

How much solar or alternator charging would run a 650 W 12 V AC all afternoon?

Solar alone on a van roof (300–500 W flat) covers roughly half to two-thirds of midday draw, so full-day off-grid AC usually leans heavily on a 60–120 A alternator/second-alternator charger plus large banks.

Why do higher-BTU campervan ACs increasingly shift from 12 V to 24 V or 48 V?

Pulling 950 W at 12.8 V requires ~74 A continuously down the ceiling pillar, whereas 48 V pulls under 20 A on far lighter roof wiring.

Can a single 100 Ah BMS run a 950 W 12 V AC unit?

At ~75–85 A steady draw plus compressor startup, a 100 A BMS operates near ceiling trip limits and drains within 70 minutes—parallel two batteries or size ≥200 A BMS capacity.