Prevent low-voltage alternator charger dropouts across long van chassis runs
Smart 60 A DC-to-DC battery chargers draw ~60–68 A continuously from the starter battery when charging a depleted LiFePO4 house bank, and long 12–16 ft runs from engine bay to rear wheel well create substantial voltage drop.
At 60 A over 16 ft one-way (32 ft round-trip including ground return), 2 AWG marine copper is required to keep loop drop at 2.71% (0.347 V) below a 3% ceiling with a 75 A MRBF or 80 A ANL fuse.
Formulas
3% drop budget on 12.8 V = 0.384 V max loop loss16 ft one-way (32 ft loop) on 2 AWG = 0.347 V (2.71% drop)8 ft short run @ 60 A = 4 AWG (2.16% drop, 75 A MRBF / 80 A ANL)
Worked example
Over a 16 ft one-way van run at 60 A (12.8 V), 2 AWG keeps voltage drop to 2.71% (0.347 V) with a 75 A MRBF / 80 A ANL / 110 A Class T fuse; cutting run length to 8 ft lets 4 AWG pass at 2.16% drop.