LFP SOC Knee vs. Plateau Voltage Sensitivity

Use the lower knee of the illustrative LFP curve to compare voltage sensitivity against the flatter mid-SOC interval.

Jump to results

Inputs

Coulomb counting
Discharge is positive. Charge is negative.
Voltage measurement and rest
Use a nonnegative bound. Selected, ±5 mV and ±15 mV are compared.
Use an absolute amplitude fitted to your cell relaxation trace.
Illustrative first-order parameter.
Percentage points of SOC.

Results

Estimates
Signed coulomb-count SOC error-1.212 pp
Current offset error
2.4 Ah
Current gain error
0.024 Ah
Integrated measurement error
2.424 Ah
Reference / indicated end SOC
5.6 % / 4.39 %
Illustrative LFP and NMC cell OCV
2.8 2.8 3.5 3.5 4.2 4.2V V 0 SOC (%) 100
  • LFP
  • NMC

8 % SOC · LFP 3.166 V · NMC 3.404 V

Voltage sensitivity and OCV correction
MetricLFPNMC
Cell OCV3.166 V3.404 V
Local SOC sensitivity0.045 pp/mV0.036 pp/mV
SOC error with ±5 mV-0.23 to +0.23 pp-0.18 to +0.18 pp
SOC error with ±15 mV-0.68 to +0.68 pp-0.54 to +0.54 pp
SOC error with selected noise-0.23 to +0.23 pp-0.18 to +0.18 pp
Modeled rest to reach target0 min0 min

The curve and rest inputs are illustrative. Hysteresis and temperature error can further reduce the OCV correction budget.

LFP SOC Knee vs. Plateau Voltage Sensitivity method

Use the lower knee of the illustrative LFP curve to compare voltage sensitivity against the flatter mid-SOC interval.

The illustrative monotonic LFP and NMC curves show how a few millivolts of uncertainty become a larger SOC error on a flat plateau. Each curve is a synthetic example in volts per cell. Real curves depend on cell type, temperature, state of health and charge direction.

Offset integrates even near zero current. Gain error scales with the signed net current integral. The result uses constant sensor errors and a mean current over the selected interval. Capacity, initial SOC and coulombic-efficiency errors are separate effects.

The rest estimate fits a first-order exponential to the residual polarization. It inverts the curve at the requested SOC error bounds, subtracts the voltage error budget and solves for the required wait. Use cell-specific test data and include hysteresis or temperature model error in the voltage budget when appropriate.

Formulas

  • ΔAh = (offset[mA]/1000 + mean discharge current × gain[%]/100) × operating hours
  • ΔSOC[% points] = −100 × ΔAh / usable capacity[Ah]
  • Local voltage sensitivity ≈ 1 / (dOCV/dSOC); noise bounds = inverse OCV(OCV ± noise) − reference SOC
  • Modeled rest = τ × ln(initial polarization / remaining voltage budget) when the budget is positive and the initial residual exceeds it

Worked example

The starting scenario gives -1.212 percentage points of indicated SOC drift. Its local LFP and NMC OCV sensitivities are 0.045 and 0.036 pp/mV, respectively.

Engineering references

Frequently asked questions

Why can a knee be easier to anchor than the plateau?

A steeper OCV slope maps the same voltage uncertainty to fewer SOC percentage points. The actual anchor region varies by cell and temperature.

In the LFP SOC Knee vs. Plateau Voltage Sensitivity example, why is OCV correction weak on the LFP plateau?

A small voltage difference maps to a large SOC range. The upper and lower knees generally provide stronger voltage information.

In the LFP SOC Knee vs. Plateau Voltage Sensitivity example, will one hour of cell rest always be enough?

The PNGV HPPC protocol records OCV during one-hour rests. The settling time needed for correction depends on the cell, temperature, prior current, voltage error budget and acceptable SOC uncertainty.