NMC OCV-to-SOC Voltage Noise Calculator

Compare NMC and LFP SOC ambiguity at 65% using a ±15 mV per-cell measurement budget.

Jump to results

Inputs

Coulomb counting
Discharge is positive. Charge is negative.
Voltage measurement and rest
Use a nonnegative bound. Selected, ±5 mV and ±15 mV are compared.
Use an absolute amplitude fitted to your cell relaxation trace.
Illustrative first-order parameter.
Percentage points of SOC.

Results

Estimates
Signed coulomb-count SOC error-0.66 pp
Current offset error
1.2 Ah
Current gain error
0.12 Ah
Integrated measurement error
1.32 Ah
Reference / indicated end SOC
53 % / 52.34 %
Illustrative LFP and NMC cell OCV
2.8 2.8 3.5 3.5 4.2 4.2V V 0 SOC (%) 100
  • LFP
  • NMC

65 % SOC · LFP 3.308 V · NMC 3.865 V

Voltage sensitivity and OCV correction
MetricLFPNMC
Cell OCV3.308 V3.865 V
Local SOC sensitivity2 pp/mV0.111 pp/mV
SOC error with ±5 mV-10 to +6.25 pp-0.56 to +0.56 pp
SOC error with ±15 mV-30 to +11.25 pp-1.67 to +1.67 pp
SOC error with selected noise-30 to +11.25 pp-1.67 to +1.67 pp
Modeled rest to reach targetNo finite rest41.2 min

The curve and rest inputs are illustrative. Hysteresis and temperature error can further reduce the OCV correction budget.

NMC OCV-to-SOC Voltage Noise Calculator method

Compare NMC and LFP SOC ambiguity at 65% using a ±15 mV per-cell measurement budget.

The illustrative monotonic LFP and NMC curves show how a few millivolts of uncertainty become a larger SOC error on a flat plateau. Each curve is a synthetic example in volts per cell. Real curves depend on cell type, temperature, state of health and charge direction.

Offset integrates even near zero current. Gain error scales with the signed net current integral. The result uses constant sensor errors and a mean current over the selected interval. Capacity, initial SOC and coulombic-efficiency errors are separate effects.

The rest estimate fits a first-order exponential to the residual polarization. It inverts the curve at the requested SOC error bounds, subtracts the voltage error budget and solves for the required wait. Use cell-specific test data and include hysteresis or temperature model error in the voltage budget when appropriate.

Formulas

  • ΔAh = (offset[mA]/1000 + mean discharge current × gain[%]/100) × operating hours
  • ΔSOC[% points] = −100 × ΔAh / usable capacity[Ah]
  • Local voltage sensitivity ≈ 1 / (dOCV/dSOC); noise bounds = inverse OCV(OCV ± noise) − reference SOC
  • Modeled rest = τ × ln(initial polarization / remaining voltage budget) when the budget is positive and the initial residual exceeds it

Worked example

The starting scenario gives -0.66 percentage points of indicated SOC drift. Its local LFP and NMC OCV sensitivities are 2 and 0.111 pp/mV, respectively.

Engineering references

Frequently asked questions

Can a voltage-noise interval be asymmetric in SOC?

Yes. Different OCV slopes on either side of the reference point can map the same positive and negative voltage errors to different SOC errors.

In the NMC OCV-to-SOC Voltage Noise Calculator example, why is OCV correction weak on the LFP plateau?

A small voltage difference maps to a large SOC range. The upper and lower knees generally provide stronger voltage information.

In the NMC OCV-to-SOC Voltage Noise Calculator example, will one hour of cell rest always be enough?

The PNGV HPPC protocol records OCV during one-hour rests. The settling time needed for correction depends on the cell, temperature, prior current, voltage error budget and acceptable SOC uncertainty.