400 V EV Insulation Resistance and ISO 6469-3 Context

Convert a 400 V traction-bus bridge result to Ω/V and compare isolated DC and combined-bus reference levels.

Jump to results

Inputs

Isolation bridge measurements
Use the applicable working or nominal operating voltage for the procedure.
Charge temperature and rate scenario
Use cell and system limits. All default rates and temperatures are illustrative.

Results

Estimates
Weaker pole isolation250 Ω/V
Positive to chassis (Riso+ / R1)
100 kΩ
Negative to chassis (Riso− / R2)
300 kΩ
Parallel equivalent
75 kΩ
Measured bus / shunt voltage shift
400 V / 60 V
Selected threshold
100 Ω/V · 40 kΩ
Isolation comparison
Meets selected threshold
500 Ω/V reference
Below reference
Charge rate cap at entered temperature
0.5 C
Requested charge rate
0.5 C · Within entered limit
Estimated rail isolation and selected threshold
Positive to chassis 100 kΩ Negative to chassis 300 kΩ Selected threshold 40 kΩ

The numeric threshold is a screening comparison. Use the applicable bus topology, test procedure and qualification requirements.

400 V EV Insulation Resistance and ISO 6469-3 Context method

Convert a 400 V traction-bus bridge result to Ω/V and compare isolated DC and combined-bus reference levels.

Enter positive magnitudes for both unloaded pole-to-chassis voltage readings and for the loaded reading on the pole shunted by the known resistor. The model treats the bus voltage as constant and the meter impedance as negligible loading relative to the leakage paths. Ensure the measured voltage shift is resolved by the instrument and the measurements have settled.

The result compares the weaker rail insulation with the chosen Ω/V screen and reports parallel equivalent separately. UN Regulation No. 100 Rev. 3 specifies 100 Ω/V for applicable galvanically separated DC buses and generally 500 Ω/V for combined AC/DC buses, subject to its listed exceptions. Annex 5 uses the higher-magnitude pole for its shunt procedure. ISO 6469-3 covers electrical safety for road vehicles. Apply the standard and test procedure relevant to the system and jurisdiction.

The charge-rate example is independent of the bridge measurements. At low cell temperature graphite plating risk can increase. At high cell temperature, charging can add heat and reduce thermal margin. Enter validated cell and pack thresholds for the actual design.

Formulas

  • Ubus = Vp + Vn using the unloaded voltage magnitudes; Rparallel = Rf × (Vbefore/Vafter − 1)
  • Riso+ (R1) = Rparallel × Ubus / Vn; Riso− (R2) = Rparallel × Ubus / Vp
  • Isolation in Ω/V = 1000 × min(Riso+, Riso−) / reference voltage, with resistances in kΩ
  • Illustrative charge cap = zero outside the charge window, nominal × edge fraction in cold or hot bands, and nominal inside the normal band

Worked example

The starting scenario gives 100 kΩ positive and 300 kΩ negative pole insulation, or 250 Ω/V on the weaker rail. The separate temperature scenario caps charging at 0.5 C.

Engineering references

Frequently asked questions

What resistance is equivalent to 100 Ω/V at 400 V?

The screening resistance is 40 kΩ. At 500 Ω/V it is 200 kΩ for the same reference voltage.

In the 400 V EV Insulation Resistance and ISO 6469-3 Context example, which pole is shunted in the regulatory-style bridge check?

UN Regulation No. 100 Annex 5 selects the pole with the higher unloaded voltage magnitude. The idealized solver accepts either pole and calls out departures from the comparison procedure.

In the 400 V EV Insulation Resistance and ISO 6469-3 Context example, does 500 Ω/V apply to every DC pack?

It can be specified as a conservative design target. Applicable vehicle minimums depend on bus topology and documented protections. Stationary installations require their own applicable rules.