800 V EV Isolation Resistance at 500 Ω/V method
Compare the weaker leakage path on an 800 V dual-rail bus with a 500 Ω/V reference.
Enter positive magnitudes for both unloaded pole-to-chassis voltage readings and for the loaded reading on the pole shunted by the known resistor. The model treats the bus voltage as constant and the meter impedance as negligible loading relative to the leakage paths. Ensure the measured voltage shift is resolved by the instrument and the measurements have settled.
The result compares the weaker rail insulation with the chosen Ω/V screen and reports parallel equivalent separately. UN Regulation No. 100 Rev. 3 specifies 100 Ω/V for applicable galvanically separated DC buses and generally 500 Ω/V for combined AC/DC buses, subject to its listed exceptions. Annex 5 uses the higher-magnitude pole for its shunt procedure. ISO 6469-3 covers electrical safety for road vehicles. Apply the standard and test procedure relevant to the system and jurisdiction.
The charge-rate example is independent of the bridge measurements. At low cell temperature graphite plating risk can increase. At high cell temperature, charging can add heat and reduce thermal margin. Enter validated cell and pack thresholds for the actual design.
Formulas
Ubus = Vp + Vn using the unloaded voltage magnitudes; Rparallel = Rf × (Vbefore/Vafter − 1)Riso+ (R1) = Rparallel × Ubus / Vn; Riso− (R2) = Rparallel × Ubus / VpIsolation in Ω/V = 1000 × min(Riso+, Riso−) / reference voltage, with resistances in kΩIllustrative charge cap = zero outside the charge window, nominal × edge fraction in cold or hot bands, and nominal inside the normal band
Worked example
The starting scenario gives 533.33 kΩ positive and 320 kΩ negative pole insulation, or 400 Ω/V on the weaker rail. The separate temperature scenario caps charging at 0.5 C.