Screen boat DC trunks for ABYC E-11 3% drop and 105 °C marine insulation
ABYC E-11 requires critical marine DC feeders—navigation panels, bilge pumps, windlass controls and main house trunks—to stay within 3% round-trip voltage drop while honoring 105 °C marine-grade stranded copper bundle ampacities.
At 12.8 V and 80 A over a 12 ft one-way run (24 ft round-trip), the 3% budget is only 0.384 V. Voltage drop—not thermal ampacity—governs the cable choice and requires 2 AWG tinned copper paired with a 100 A MRBF or Class T fuse.
Formulas
3% marine drop budget @ 12.8 V = 0.384 V across 24 ft (7.315 m) loopABYC 125% overcurrent protection target = 80 A × 1.25 = 100 ASwitching the same power to 25.6 V cuts loop voltage drop percentage by 4×
Worked example
An 80 A 12.8 V house feeder running 12 ft one-way selects 2 AWG 105 °C marine copper (2.71% drop, 147 A bundle ampacity) with a 100 A ANL/MRBF or 110 A Class T fuse screen.