ABYC E-11 Marine 12V / 24V Battery Cable Gauge & Voltage Drop Calculator

Size 105 °C tinned marine copper DC wiring under ABYC E-11 bundled ampacity, 3% critical-load voltage drop and MRBF / Class T fuse screening.

Jump to results

Inputs

Circuit and voltage drop
Use full charge voltage when screening DC fuses.
Cable and installation
Enter the combined ambient and bundling adjustment.

Results

Estimates
Minimum reference gauge2 AWG
Round-trip length
7.32 m
Fuse target at 125% load
100 A
Copper or aluminum area
33.63 mm²
Calculated drop
0.35 V · 2.71%
Cable loss
27.77 W
Adjusted ampacity
147 A
DC circuit loop schematic · Copper · Marine bundle2 AWG · 2.71% drop
DC POWER LOOP · COPPER · MARINE BUNDLE · 105 °C PASS · 2 AWG (33.6 mm²) BATTERY / SOURCE 12.8 V Max 14.6 V DC Draw 80 A MAIN FUSE Class T 110 A Ceiling 125 V DC 2 AWG · 33.6 mm² Cu 12 ft 1-way · 0.59 Ω/km @ 60 °C LOAD / INVERTER 12.45 V At load terminals 1,024 W · 80 A Return conductor (2 AWG · 7.32 m round-trip) · Drop −0.35 V VOLTAGE DROP VS. 3% 2.71% Drop 0.35 V / 0.38 V max Loss 27.8 W AMPACITY (100% DERATE) 80 / 147 A 125% fuse target 100 A Fuse cap 147 A
Neighboring gauges
AWGmm²Ω/kmAmpacityDropScreen
421.150.943112 A4.31%Outside limits
326.670.748126 A3.42%Outside limits
233.630.593147 A2.71%Pass
142.410.47172 A2.15%Pass
1/053.480.373200 A1.71%Pass
Main fuse candidates
TypeCurrent candidateExample DC ceiling
Class T110 A125 V
ANL100 A32 V
MRBF100 A58 V

Fuse candidates account for the entered 14.6 V circuit maximum. Check available fault current, interrupt rating, terminals and applicable installation rules.

Engineering Bill of Materials (BOM)
CategorySpecificationQtySizing basis
DC Cable Run2 AWG (33.63 mm²) copper cable, 105 °C (marine)7.32 m loop (12 ft × 2)2.71% drop (0.35 V) · 147 A ampacity
Main DC Fuse & HolderClass T 110 A fuse (125 V DC) + compatible holder1 set125% load (100 A) screened @ 14.6 V max
Lugs & Terminations2 AWG tinned copper compression lugs + heat shrink4 lugsRated ≥105 °C terminal limit for copper
DC Busbar100 A DC distribution busbar pair with insulated cover1 pair (+ / −)Covers ≥100 A continuous feeder rating
DC Isolator Switch100 A DC load-break isolator (≥15 V DC)1 unitManual disconnect for 80 A 12.8 V circuit

Screen boat DC trunks for ABYC E-11 3% drop and 105 °C marine insulation

ABYC E-11 requires critical marine DC feeders—navigation panels, bilge pumps, windlass controls and main house trunks—to stay within 3% round-trip voltage drop while honoring 105 °C marine-grade stranded copper bundle ampacities.

At 12.8 V and 80 A over a 12 ft one-way run (24 ft round-trip), the 3% budget is only 0.384 V. Voltage drop—not thermal ampacity—governs the cable choice and requires 2 AWG tinned copper paired with a 100 A MRBF or Class T fuse.

Formulas

  • 3% marine drop budget @ 12.8 V = 0.384 V across 24 ft (7.315 m) loop
  • ABYC 125% overcurrent protection target = 80 A × 1.25 = 100 A
  • Switching the same power to 25.6 V cuts loop voltage drop percentage by 4×

Worked example

An 80 A 12.8 V house feeder running 12 ft one-way selects 2 AWG 105 °C marine copper (2.71% drop, 147 A bundle ampacity) with a 100 A ANL/MRBF or 110 A Class T fuse screen.

Engineering references

Frequently asked questions

Why does ABYC E-11 specify 3% drop for house panels vs. 10% for non-critical loads?

Electronics, inverters, refrigeration compressors and navigation gear can brown out or fault on low voltage; 3% keeps terminal voltage healthy even at 20% battery state of charge.

Do engine-room marine cables need extra temperature derating?

Yes—ABYC E-11 applies an ~0.82–0.85 ambient correction factor inside 50 °C machinery spaces and additional derating when more than two current-carrying cables are bundled in a loom.

Should marine LiFePO4 banks use MRBF or Class T fuses?

High-capacity LiFePO4 house banks (>200 Ah) have low internal impedance and benefit from a Class T fuse (20 kA AIC) at the main bank post, with MRBF fuses suited to individual branch circuits.