16S2P 48V 560Ah (28.67 kWh) Off-Grid Solar Bank Calculator

Design a 32-cell 16S2P EVE LF280K 48 V home solar bank: 28.67 kWh storage, 560 A max continuous output, 2.0 mΩ stack impedance and 173 kg cell mass.

Jump to results

Inputs

Pack layout
Unit specifications

Results

Estimates
Nominal pack voltage51.2 V
Full charge
58.4 V
Discharge cutoff
40 V
Nominal capacity
560 Ah
Nominal energy
28.672 kWh
Unit weight only
173.44 kg
Equivalent unit resistance
2 mΩ
Unit-limited continuous output
560 A / 28.67 kW
BMS sizing for full unit output
16S · ≥560 A
Pack electrical schematic · 16S2PScroll ↔ · 16S
PACK VOLTAGE 51.2 V 40–58.4 V PACK CAPACITY 560 Ah 28.67 kWh IMPEDANCE 2 mΩ 32× cells CONT. OUTPUT 560 A 28.67 kW max CELL MATRIX ENCLOSURE · 16S2PS1 − + − +S2 − + − +S3 − + − +S4 − + − +S5 − + − +S6 − + − +S7 − + − +S8 − + − +S9 − + − +S10 − + − +S11 − + − +S12 − + − +S13 − + − +S14 − + − +S15 − + − +S16 − + − + B− B+ BMS · 16S BALANCING & FET ≥ 560 A continuous 17 sense taps (B0–B16) MAIN BUS & PROTECTION REF. 125% fuse ≥ 700 A Interrupt rating ≥ 59 V DC

Cell-limited estimates assume matched units and even current sharing. Set charge, BMS, busbar and thermal limits from your actual hardware.

Engineering Bill of Materials (BOM)
CategorySpecificationQtySizing basis
Cells / Modules3.2 V 280 Ah matched cells (16S2P)32 pcs51.2 V nominal · 28.67 kWh · 173.4 kg
BMS16S BMS, ≥560 A continuous (charge & discharge)1 unitFull charge 58.4 V · 560 A (1C)
Main DC Fuse & HolderClass T 700 A fuse & holder (≥59 V DC)1 set125% of 560 A continuous output @ 58.4 V max
Main DC Cable RunDual parallel 2/0–4/0 AWG copper legs feeder cable + ring lugs2 runs (+ / −)Sized for ≥700 A pack-to-busbar feeder
Busbars & Interconnects1000 A tinned copper cell busbars + terminal covers31 links16S2P interconnects rated ≥700 A
DC Isolator Switch700 A DC battery disconnect switch (≥59 V DC)1 unitService isolation for 51.2 V pack

Scale up to a whole-home 28.7 kWh 48 V solar storage bank cleanly

Thirty-two EVE LF280K cells configured in 16S2P (two parallel banks of 16 cells, or 2P16S pairs) give 51.2 V nominal, 560 Ah, and 28.672 kWh—enough reserve for full whole-home backup through cloudy days.

Adding the second parallel path halves total cell-stack resistance to 2.0 mΩ and expands continuous C-rate capacity to 560 A (~28.7 kW DC), easily loafing behind 10–15 kW hybrid inverters.

Formulas

  • 32 cells (16S × 2P): 51.2 V × 560 Ah = 28.672 kWh
  • Cell mass = 32 × 5.42 kg = 173.44 kg
  • 16S3P expansion = 840 Ah / 43.008 kWh (260.16 kg)

Worked example

A 16S2P LF280K bank yields 51.2 V nominal, 560 Ah, 28.672 kWh, 173.44 kg bare cell weight and 560 A rated capability; scaling to 16S3P reaches 840 Ah and 43.008 kWh.

Frequently asked questions

Is building two 16S1P packs with dual 200 A BMS units better than one 2P16S 400 A BMS?

Two independent 16S1P packs (2 × 14.34 kWh) isolate faults, keep assembly weight under 95 kg per rack, and connect via standard 175–200 A BMS hardware.

What happens if one 16S1P bank drops out for maintenance?

The second parallel bank stays live to supply 14.34 kWh at reduced surge capacity while you service or top-balance the isolated rack.

Does 28.67 kWh usable require 100% depth of discharge?

At typical 85–90% usable SOC cycling, a 28.67 kWh 16S2P bank comfortably delivers 24.4–25.8 kWh daily without hitting low-voltage cutoff alarms.