Size EG4 12kPV 48 V DC battery feeders for 8 kW inverter output
The EG4 12kPV delivers 8,000 W continuous AC output from battery (167 A max rated battery discharge, modeled at 175 A with low-voltage margin) and up to 12 kW PV input, sitting neatly between 6 kW off-grid units and the 18kPV.
At 175 A over a 6 ft one-way run, 125% continuous sizing targets 218.75 A. Under 90 °C marine copper, 3/0 AWG carries 231 A with 0.29% voltage drop and pairs with a 225 A Class T fuse; under 75 °C NEC raceway lugs, 4/0 AWG (230 A) is required.
Formulas
DC discharge @ 8 kW / 93% eff / 49 V ≈ 175 A125% continuous NEC/Class T target = 175 × 1.25 = 218.75 A → 225 A Class T6 ft one-way loop = 3.658 m · 3/0 AWG copper drop ≈ 0.15 V (0.29%)
Worked example
An EG4 12kPV at 175 A over 6 ft one-way returns 3/0 AWG copper (231 A ampacity, 0.29% drop) and a 225 A Class T fuse in 90 °C marine insulation, or 4/0 AWG copper in 75 °C NEC raceway conduit.