4S EVE LF280K 12V (12.8V 280Ah) DIY LiFePO4 Battery Calculator

Model a 4S1P or 4S2P 12.8 V campervan/marine battery using 280 Ah LiFePO4 cells: 3.58 kWh, 10–14.6 V operating limits and 4S BMS sizing.

Jump to results

Inputs

Pack layout
Unit specifications

Results

Estimates
Nominal pack voltage12.8 V
Full charge
14.6 V
Discharge cutoff
10 V
Nominal capacity
280 Ah
Nominal energy
3.584 kWh
Unit weight only
21.68 kg
Equivalent unit resistance
1 mΩ
Unit-limited continuous output
280 A / 3.58 kW
BMS sizing for full unit output
4S · ≥280 A
Pack electrical schematic · 4S1P
PACK VOLTAGE 12.8 V 10–14.6 V PACK CAPACITY 280 Ah 3.58 kWh IMPEDANCE 1 mΩ 4× cells CONT. OUTPUT 280 A 3.58 kW max CELL MATRIX ENCLOSURE · 4S1PS1 − +S2 − +S3 − +S4 − + B− B+ BMS · 4S BALANCING & FET ≥ 280 A continuous 5 sense taps (B0–B4) MAIN BUS & PROTECTION REF. 125% fuse ≥ 350 A Interrupt rating ≥ 15 V DC

Cell-limited estimates assume matched units and even current sharing. Set charge, BMS, busbar and thermal limits from your actual hardware.

Engineering Bill of Materials (BOM)
CategorySpecificationQtySizing basis
Cells / Modules3.2 V 280 Ah matched cells (4S1P)4 pcs12.8 V nominal · 3.58 kWh · 21.7 kg
BMS4S BMS, ≥280 A continuous (charge & discharge)1 unitFull charge 14.6 V · 280 A (1C)
Main DC Fuse & HolderClass T / ANL 350 A fuse & holder (≥15 V DC)1 set125% of 280 A continuous output @ 14.6 V max
Main DC Cable RunDual parallel 2/0–4/0 AWG copper legs feeder cable + ring lugs2 runs (+ / −)Sized for ≥350 A pack-to-busbar feeder
Busbars & Interconnects400 A tinned copper cell busbars + terminal covers3 links4S1P interconnects rated ≥350 A
DC Isolator Switch400 A DC battery disconnect switch (≥15 V DC)1 unitService isolation for 12.8 V pack

Pack 3.58 kWh into a compact 21.7 kg 12.8 V DIY campervan battery

Four EVE LF280K cells in 4S1P pack 3.584 kWh into roughly the floor space of two Group 31 AGM batteries while cutting weight to 21.68 kg—delivering nearly three 100 Ah AGM packs of usable energy.

Pair with a 4S 200 A–280 A smart BMS and a 125 V Class T or 58 V MRBF terminal fuse sized for your largest 12 V inverter and alternator charger draw.

Formulas

  • Nominal pack = 4 × 3.2 V = 12.8 V (cutoff 10.0 V, max 14.6 V)
  • Energy = 12.8 V × 280 Ah = 3,584 Wh (3.584 kWh)
  • Stack weight = 4 × 5.42 kg = 21.68 kg

Worked example

A 4S1P LF280K build provides 12.8 V nominal (10.0–14.6 V), 280 Ah, 3.584 kWh, 21.68 kg and 1.0 mΩ internal stack resistance; expanding to 4S2P yields 560 Ah (7.168 kWh) at 12.8 V.

Frequently asked questions

Can a 4S1P 280 Ah DIY pack run a 3,000 W 12 V inverter?

At 280 A 1 C cell rating (~3,584 W DC), a single 200 A BMS will trip before full 3,000 W AC output (~260–290 A DC); use a 250–300 A BMS/inverter limit or step up to 24 V/48 V.

Do prismatic LF280K cells in a van still need a compression fixture?

Yes—mild uniform fixture compression (~300 kgf per manufacturer spec) restricts pouch swelling and holds terminal busbars stress-free during rough road vibration.

Why add low-temperature charge disconnect on a 4S van BMS?

Charging LiFePO4 below 0 °C plates metallic lithium onto the anode permanently, so low-temp FET cutoff is mandatory in four-season vans.