24V 200Ah LiFePO4 40A / 80A Charge Time & Balancing Calculator

Estimate 10% to 100% CC/CV bulk and absorption recharge hours for a 5.12 kWh 24 V 200 Ah marine/RV battery at 40 A vs. 80 A.

Jump to results

Inputs

CC/CV charge profile
Cell imbalance
Record context. LFP voltage alone cannot determine ΔAh.

Results

Estimates
Estimated full charge interval5:06 h:mm
Constant-current phase
4:05 h:mm
Constant-voltage phase
1:01 h:mm
Capacity imbalance
2 Ah
Active balancing time
1 h
Balance windows
1
Effective balancing time by current
30 mA 66.667 h 100 mA 20 h 1,000 mA 2 h 5,000 mA 0.4 h
Balancing current comparison
Balance mode exampleActive hoursCycles
Passive · 30 mA66.6734
Passive · 100 mA2010
Active · 1,000 mA21
Active · 5,000 mA0.41

Balancing time uses effective net correction current and only counts windows where balancing is active.

Time deep 10%→100% 24 V bank recovery across solar and shore chargers

Replenishing an 8S 24 V 200 Ah bank (5.12 kWh) from 10% to 100% SOC adds 180 net amp-hours—delivering 160 Ah in full-rate CC bulk up to 90% SOC and 20 Ah in constant-voltage tapering.

With 98% charge coulombic efficiency and a 50% average CV rate, a single 40 A (~1.1 kW) charger finishes in 5.10 hours (4.08 h CC + 1.02 h CV), while dual 40 A solar + alternator chargers (80 A total) recharge in 2.55 hours.

Formulas

  • CC bulk = (200 × 80%) ÷ (40 A × 98%) = 4.08 h
  • CV taper = (200 × 10%) ÷ (39.2 A × 50%) = 1.02 h
  • Total 10%→100% time = 5.10 h @ 40 A (halves to 2.55 h @ 80 A)

Worked example

Charging 200 Ah from 10% to 100% SOC at 40 A takes 5.10 hours (4.08 h CC + 1.02 h CV); upgrading to 80 A combined charging completes recovery in 2.55 hours while 2 A active balancing closes a 2 Ah offset in 1 hour.

Frequently asked questions

How many solar PV watts yield 40 A continuous into a 25.6 V battery?

At 28.4 V absorption voltage (~1,136 W DC delivered), expect roughly 1,450–1,600 W of roof or ground panels in strong midday sun.

Why does 40 A at 24 V fill twice the watt-hours per hour compared to 40 A at 12 V?

Ampere-hours scale with nominal voltage: 40 A into 25.6 V delivers ~1,024 Wh/h, double the ~512 Wh/h of a 40 A 12 V charger.

Should two 12 V 200 Ah batteries wired in series for 24 V have an inter-battery balancer?

Yes—series-strung 12 V drop-in modules benefit enormously from a 24 V active battery equalizer so one pack never hits high-voltage disconnect early at 28.8 V.