16S EVE MB56 628Ah 48V LiFePO4 Battery Pack Calculator

Model a 16S1P or 16S2P EVE MB56 628 Ah giant prismatic LiFePO4 pack: 51.2 V nominal, 32.154 kWh energy, 182.4 kg cell mass and 0.5C BMS sizing.

Jump to results

Inputs

Pack layout
Unit specifications

Results

Estimates
Nominal pack voltage51.2 V
Full charge
58.4 V
Discharge cutoff
40 V
Nominal capacity
628 Ah
Nominal energy
32.154 kWh
Unit weight only
182.4 kg
Equivalent unit resistance
2.88 mΩ
Unit-limited continuous output
314 A / 16.08 kW
BMS sizing for full unit output
16S · ≥314 A
Pack electrical schematic · 16S1PScroll ↔ · 16S
PACK VOLTAGE 51.2 V 40–58.4 V PACK CAPACITY 628 Ah 32.15 kWh IMPEDANCE 2.88 mΩ 16× cells CONT. OUTPUT 314 A 16.08 kW max CELL MATRIX ENCLOSURE · 16S1PS1 − +S2 − +S3 − +S4 − +S5 − +S6 − +S7 − +S8 − +S9 − +S10 − +S11 − +S12 − +S13 − +S14 − +S15 − +S16 − + B− B+ BMS · 16S BALANCING & FET ≥ 314 A continuous 17 sense taps (B0–B16) MAIN BUS & PROTECTION REF. 125% fuse ≥ 393 A Interrupt rating ≥ 59 V DC

Cell-limited estimates assume matched units and even current sharing. Set charge, BMS, busbar and thermal limits from your actual hardware.

Engineering Bill of Materials (BOM)
CategorySpecificationQtySizing basis
Cells / Modules3.2 V 628 Ah matched cells (16S1P)16 pcs51.2 V nominal · 32.15 kWh · 182.4 kg
BMS16S BMS, ≥314 A continuous (charge & discharge)1 unitFull charge 58.4 V · 314 A (0.5C)
Main DC Fuse & HolderClass T 400 A fuse & holder (≥59 V DC)1 set125% of 314 A continuous output @ 58.4 V max
Main DC Cable RunDual parallel 2/0–4/0 AWG copper legs feeder cable + ring lugs2 runs (+ / −)Sized for ≥393 A pack-to-busbar feeder
Busbars & Interconnects400 A tinned copper cell busbars + terminal covers15 links16S1P interconnects rated ≥393 A
DC Isolator Switch400 A DC battery disconnect switch (≥59 V DC)1 unitService isolation for 51.2 V pack

Size a 32 kWh single-string 16S EVE MB56 628 Ah energy storage pack

EVE’s MB56 628 Ah prismatic cell doubles the capacity of 314 Ah MB31 cells inside a single 11.4 kg aluminum casing, enabling a 32.154 kWh 48 V home ESS in a clean 16S1P string with only 16 cells and one 16S BMS.

At 0.5 C continuous discharge, a single 16S1P MB56 string supports up to 314 A (~16.08 kW DC), exceeding standard 200 A single-pack BMS ratings—so either select a 300 A+ contactor-based BMS or cap inverter continuous discharge to your 200 A BMS ceiling.

Formulas

  • Nominal energy = 16 × 3.2 V × 628 Ah ÷ 1,000 = 32.154 kWh
  • Pack resistance (cells only) = 16 × 0.18 mΩ = 2.880 mΩ
  • 0.5 C cell-limited output = 628 × 0.5 = 314 A (16.08 kW DC)

Worked example

Sixteen EVE MB56 628 Ah cells in 16S1P yield 51.2 V nominal, 58.4 V full charge, 32.154 kWh nominal energy, 182.4 kg cell weight, 2.88 mΩ equivalent resistance and 314 A (0.5 C) cell-limited current.

Frequently asked questions

Can a standard 200 A JK BMS run a 16S1P EVE MB56 628 Ah pack?

Yes as long as your inverter’s continuous DC draw stays at or below 200 A (~10 kW). The cells simply run at a gentle ~0.32 C, improving thermal margin and cycle life.

How much compression force and enclosure strength do 16 MB56 cells require?

At 182.4 kg of cells alone (over 200 kg with steel box, busbars and BMS), use heavy-duty casters or floor-mounted steel racking and follow EVE’s fixture compression spec to control swelling.

How long does a 2 A active balancer take to equalize a 628 Ah MB56 cell?

A 1% SOC offset on a 628 Ah cell is 6.28 Ah—requiring 3.14 hours of active 2 A transfer, making top-balancing cells before assembly strongly recommended.