16S EVE LF304 48V (15.56 kWh) LiFePO4 Battery Pack Calculator

Configure a 16S1P or 16S2P 48 V bank with EVE LF304 304 Ah LiFePO4 cells: 51.2 V nominal, 15.56 kWh, 87.8 kg cell weight and 304 A 1C BMS rating.

Jump to results

Inputs

Pack layout
Unit specifications

Results

Estimates
Nominal pack voltage51.2 V
Full charge
58.4 V
Discharge cutoff
40 V
Nominal capacity
304 Ah
Nominal energy
15.565 kWh
Unit weight only
87.84 kg
Equivalent unit resistance
4 mΩ
Unit-limited continuous output
304 A / 15.56 kW
BMS sizing for full unit output
16S · ≥304 A
Pack electrical schematic · 16S1PScroll ↔ · 16S
PACK VOLTAGE 51.2 V 40–58.4 V PACK CAPACITY 304 Ah 15.56 kWh IMPEDANCE 4 mΩ 16× cells CONT. OUTPUT 304 A 15.56 kW max CELL MATRIX ENCLOSURE · 16S1PS1 − +S2 − +S3 − +S4 − +S5 − +S6 − +S7 − +S8 − +S9 − +S10 − +S11 − +S12 − +S13 − +S14 − +S15 − +S16 − + B− B+ BMS · 16S BALANCING & FET ≥ 304 A continuous 17 sense taps (B0–B16) MAIN BUS & PROTECTION REF. 125% fuse ≥ 380 A Interrupt rating ≥ 59 V DC

Cell-limited estimates assume matched units and even current sharing. Set charge, BMS, busbar and thermal limits from your actual hardware.

Engineering Bill of Materials (BOM)
CategorySpecificationQtySizing basis
Cells / Modules3.2 V 304 Ah matched cells (16S1P)16 pcs51.2 V nominal · 15.56 kWh · 87.8 kg
BMS16S BMS, ≥304 A continuous (charge & discharge)1 unitFull charge 58.4 V · 304 A (1C)
Main DC Fuse & HolderClass T 400 A fuse & holder (≥59 V DC)1 set125% of 304 A continuous output @ 58.4 V max
Main DC Cable RunDual parallel 2/0–4/0 AWG copper legs feeder cable + ring lugs2 runs (+ / −)Sized for ≥380 A pack-to-busbar feeder
Busbars & Interconnects400 A tinned copper cell busbars + terminal covers15 links16S1P interconnects rated ≥380 A
DC Isolator Switch400 A DC battery disconnect switch (≥59 V DC)1 unitService isolation for 51.2 V pack

Compare EVE LF304 304 Ah 16S packs against LF280K and MB31 builds

EVE LF304 prismatic LiFePO4 cells bridge the gap between 280 Ah LF280K and 314 Ah MB31 enclosures, giving 15.565 kWh in a standard 16S1P 51.2 V stack at roughly 87.84 kg bare cell mass.

At a 1 C rating, sixteen LF304 cells sustain 304 A continuous (15.56 kW DC), while expanding to 16S2P raises bank storage to 31.130 kWh (608 Ah) and cuts cell-stack resistance down to 2.0 mΩ.

Formulas

  • 16S1P stored energy = 51.2 V × 304 Ah ÷ 1,000 = 15.5648 kWh
  • Pack mass = 16 × 5.49 kg = 87.84 kg (175.68 kg for 16S2P)
  • 16S2P nominal bank = 608 Ah / 31.1296 kWh

Worked example

Sixteen EVE LF304 304 Ah cells in 16S1P deliver 51.2 V nominal (58.4 V peak), 15.565 kWh, 87.84 kg and a 304 A minimum 16S BMS; doubling to 16S2P provides 31.130 kWh.

Frequently asked questions

Are EVE LF304 physical busbar spacing dimensions interchangeable with LF280K racks?

Both families follow ~174 mm × 72 mm × 207 mm prismatic footprints with 72 mm center spacing; always verify threaded M6 vs. laser-welded dual-hole stud height before ordering fixtures.

Do I still cap daily absorption at 55.2–56.8 V on LF304 packs?

Yes—setting 3.45–3.55 V/cell minimizes high-voltage electrolyte stress while hitting >98% usable capacity and clean BMS top balancing.

Should two parallel LF304 packs use dual 150–200 A BMS units instead of one 300 A unit?

Dual 16S1P racks keep per-module handling lighter and allow servicing one rack while the parallel pack stays live.